Skip to main content
U.S. flag

An official website of the United States government

Aquifer-test analysis of the upper aquifer of the Potomac-Raritan-Magothy aquifer system, Union Beach Borough, Monmouth County, New Jersey

January 1, 1989

The hydraulic properties of the upper aquifer of the Potomac-Raritan-Magothy aquifer system and of the overlying and underlying confining units were determined from and aquifer test in the vicinity of Union Beach Borough, New Jersey, near Raritan Bay. The April 1986 test included the pumping of 2 test wells for 72 hours at a combined discharge rate of 1,375 gal/min, and the measurement of water levels in 10 observation wells. No lateral recharge boundary in Raritan Bay affected the observed water-level changes. Assuming leaky artesian conditions, the average transmissivity and storage coefficient of the upper aquifer are 7,754 sq ft/day and 0.00044 respectively. The leakance of the combined confining units ranges from 0.000030 to 0.000076/day/ft. On the basis of lithologic samples from a nearby well, the overlying and underlying confining units were assumed to have similar hydraulic properties. By using this assumption, the vertical hydraulic conductivity of the confining units ranges from 0.010 to 0.027 ft/day. 

Publication Year 1989
Title Aquifer-test analysis of the upper aquifer of the Potomac-Raritan-Magothy aquifer system, Union Beach Borough, Monmouth County, New Jersey
DOI 10.3133/wri884183
Authors A. A. Pucci, D. A. Pope, Tamara Ivahnenko
Publication Type Report
Publication Subtype USGS Numbered Series
Series Title Water-Resources Investigations Report
Series Number 88-4183
Index ID wri884183
Record Source USGS Publications Warehouse