Acoustic systems for the measurement of streamflow

January 1, 1982

Very little information is available concerning acoustic velocity meter (AVM) operation, performance, and limitations. This report provides a better understanding about the application of AVM instrumentation to streamflow measurment. Operational U.S. Geological Survey systems have proven that AVM equipment is accurate and dependable. AVM equipment has no practical upper limit of measureable velocity if sonic transducers are securely placed and adequately protected, and will measure velocitites as low as 0.1 meter per second which is normally less than the threshold level for mechanical or head-loss meters. In some situations the performance of AVM equipment may be degraded by multipath interference, signal bending, signal attenuation, and variable streamline orientation. Smaller, less-expensive, more conveniently operable microprocessor equipment is now available which should increase use of AVM systems in streamflow applications. (USGS)

Publication Year 1982
Title Acoustic systems for the measurement of streamflow
DOI 10.3133/ofr82329
Authors Antonius Laenen, Winchell Smith
Publication Type Report
Publication Subtype USGS Numbered Series
Series Title Open-File Report
Series Number 82-329
Index ID ofr82329
Record Source USGS Publications Warehouse
USGS Organization Oregon Water Science Center