Skip to main content
U.S. flag

An official website of the United States government

KONOCTI BAY FAULT ZONE, LAKE COUNTY, CALIFORNIA: A REEVALUATION.

January 1, 1984

The Konocti Bay Fault Zone (KBFZ), initially regarded by some as a promising liquid-dominated hydrothermal system, has been a disappointment as a geothermal prospect. Five exploratory wells have been drilled in the vicinity of the KBFZ, but none of them are producing thermal fluids; in fact, three have been abandoned. This may be because hydrothermal fluid discharges along the KBFZ are low. The Na-K-Ca and Na-Li geothermometers indicate that the waters discharging around Howard and Seigler Springs may have equilibrated at temperatures above 200 degree C. If boiling has occurred or is occurring, a chloride-enthalpy diagram may be appropriate. Such a diagram for the KBFZ shows that a water in excess of 250 degree C existed or may exist in the area. However, because currently measured temperatures rarely exceed 50 degree C and magnesium concentration in the water is high, very little deep high temperature water may be present. Refs.

Publication Year 1984
Title KONOCTI BAY FAULT ZONE, LAKE COUNTY, CALIFORNIA: A REEVALUATION.
Authors J. Michael Thompson
Publication Type Conference Paper
Publication Subtype Conference Paper
Index ID 70014041
Record Source USGS Publications Warehouse