Simulation of an aquifer test on the Tesuque Pueblo Grant, New Mexico

January 1, 1980

An aquifer test was designed and conducted in the anisotropic dipping beds of the Tesuque Formation on the Tesuque Pueblo Grant, N.M. The three-dimensional digital model used to analyze the test approximated the response to the test. The analysis of the geohydrology of the test site in combination with the model calibration has provided estimates of average aquifer characteristics for the group of beds penetrated at the test site; the hydraulic conductivity parallel to the beds is about 2 feet per day, the hydraulic conductivity normal to the beds is about 0.0001 foot per day or lower, the specific yield is about 0.15, and the specific storage is about 0.000002 per foot. (USGS)

Publication Year 1980
Title Simulation of an aquifer test on the Tesuque Pueblo Grant, New Mexico
DOI 10.3133/ofr801022
Authors Glenn A. Hearne
Publication Type Report
Publication Subtype USGS Numbered Series
Series Title Open-File Report
Series Number 80-1022
Index ID ofr801022
Record Source USGS Publications Warehouse