Skip to main content
U.S. flag

An official website of the United States government

Ultraviolet spectrophotometric determination of tantalum with pyrogallol

January 1, 1953

In a search for a more rapid method for the determination of tantalum in rocks and minerals, an intensive study was made of the tantalum-pyrogallol reaction recommended by Platanov and Krivoshlikov, and a better modified spectrophotometric procedure is given. The improved method consists in measuring the absorbancy of the tantalum-pyrogallol complex at 325 mμ in 4N hydrochloric acid and a fixed concentration (0.0175M) of ammonium oxalate. Beer's law is followed for the concentration range up to 40 γ per ml. Sensitivity in terms of molar absorbancy index is 4775. Most interferences are additive in character and readily correctable. Separations or major corrections are required in the presence of significant amounts of molybdenum, tungsten, antimony, and uranium. The method has been successfully applied to three ores previously analyzed by gravimetric techniques. The method affords greater speed, sensitivity, and reproducibility in the determination of tantalum in rocks and minerals. A more reliable technique for preparing standard solutions of tantalum has been developed.

Publication Year 1953
Title Ultraviolet spectrophotometric determination of tantalum with pyrogallol
DOI 10.1021/ac60084a004
Authors J. I. Dinnin
Publication Type Article
Publication Subtype Journal Article
Series Title Analytical Chemistry
Index ID 70011108
Record Source USGS Publications Warehouse