Use of field-applied quality control samples to monitor performance of a Goulden large-sample extractor/GC-MS method for pesticides in water
Since 1985, the Goulden large-sample extractor (GLSE) has been used to isolate a broad array of trace-organic contaminants from large volumes of water. In this study, field-applied quality control measures, including matrix and surrogate spikes and blanks, were used to monitor method performance from GLSE extraction through GC-MS analysis. The method was applied to the determination of multiple classes of pesticides isolated from 4- to 112-L filtered surface-water samples. Average recoveries of six surrogate compounds ranged from 84 ?? 18% for [2H10]diazinon to 15 ?? 13% for 4,4'-[2H8]DDT, the low recoveries for which were largely a result of unmonitored breakdown of this surrogate by the GC injection system. Field-matrix-spike samples were prepared by fortifying 10-L, 35-L, and 110-L filtered surface-water samples with 68 pesticides to amended concentrations of 11- to 50-ng/L each. Recoveries ranged from not detected to greater than 100%. Variability in pesticide recoveries from triplicate 10-L water samples collected at one site averaged 5.7% relative standard deviation and did not exceed 19%.Since 1985, the Goulden large-sample extractor (GLSE) has been used to isolate a broad array of trace-organic contaminants from large volumes of water. In this study, field-applied quality control measures, including matrix and surrogate spikes and blanks, were used to monitor method performance from GLSE extraction through GC-MS analysis. The method was applied to the determination of multiple classes of pesticides isolated from 4- to 112-L filtered surface-water samples. Average recoveries of six surrogate compounds ranged from 84 ?? 18% for [2H10]diazinon to 15 ?? 13% for 4,4???-[2H8]DDT, the low recoveries for which were largely a result of unmonitored breakdown of this surrogate by the GC injection system. Field-matrix-spike samples were prepared by fortifying 10-L, 35-L, and 110-L filtered surface-water samples with 68 pesticides to amended concentrations of 11- to 50-ng/L each. Recoveries ranged from not detected to greater than 100%. Variability in pesticide recoveries from triplicate 10-L water samples collected at one site averaged 5.7% relative standard deviation and did not exceed 19%.
Citation Information
Publication Year | 2000 |
---|---|
Title | Use of field-applied quality control samples to monitor performance of a Goulden large-sample extractor/GC-MS method for pesticides in water |
DOI | 10.1080/03067310008034145 |
Authors | W.T. Foreman, Paul M. Gates, G.D. Foster, F. A. Rinella, S. W. McKenzie |
Publication Type | Article |
Publication Subtype | Journal Article |
Series Title | International Journal of Environmental Analytical Chemistry |
Index ID | 70023189 |
Record Source | USGS Publications Warehouse |
USGS Organization | National Water Quality Laboratory |