Skip to main content
U.S. flag

An official website of the United States government

Variance of discharge estimates sampled using acoustic Doppler current profilers from moving boats

June 22, 2012

This paper presents a model for quantifying the random errors (i.e., variance) of acoustic Doppler current profiler (ADCP) discharge measurements from moving boats for different sampling times. The model focuses on the random processes in the sampled flow field and has been developed using statistical methods currently available for uncertainty analysis of velocity time series. Analysis of field data collected using ADCP from moving boats from three natural rivers of varying sizes and flow conditions shows that, even though the estimate of the integral time scale of the actual turbulent flow field is larger than the sampling interval, the integral time scale of the sampled flow field is on the order of the sampling interval. Thus, an equation for computing the variance error in discharge measurements associated with different sampling times, assuming uncorrelated flow fields is appropriate. The approach is used to help define optimal sampling strategies by choosing the exposure time required for ADCPs to accurately measure flow discharge.

Publication Year 2012
Title Variance of discharge estimates sampled using acoustic Doppler current profilers from moving boats
DOI 10.1061/(ASCE)HY.1943-7900.0000558
Authors Carlos M. Garcia, Leticia Tarrab, Kevin Oberg, Ricardo Szupiany, Mariano I. Cantero
Publication Type Article
Publication Subtype Journal Article
Series Title Journal of Hydraulic Engineering
Index ID 70038078
Record Source USGS Publications Warehouse
USGS Organization Office of Surface Water